High Head Boiler feed water pump, DG type horizontal single-suction multi-stage segmented centrifugal pump, used for conveying clean water and liquids with physical and chemical properties similar to water.

The Applications of High Head Boiler Feed Water Pump
The flow rate of the boiler feed water pump is 25-150m3/h, and the head can reach 480-1100 meters. It can deliver high temperature clean water below 280℃, suitable for boiler water supply, factory and city water supply. It is suitable for conveying clean water with a temperature lower than 110°C or other non-corrosive liquids with physical and chemical properties similar to water.
High pressure multistage pump is famous worked in power plant, mining dewatering, Urban drainage.
High pressure multistage pump is widely used for power plant and high pressure request pipelines and projects. Normally it's high head boiler feed water pump used for high temperature water like boiler steam water. To update the design we have the self balancing water pump type to keep the high pressure and high temperature but with easy maintence and lower spare parts cost.
STRUCTURE DIAGRAM

Sectional Arrangement
1. Suction Casing
2.Diffuser
3. Stage Casing
4. Delivery Casing
5. Impeller Of First-stage
6.Impeller
7.Balance Disc
8. Balance Ring
9. Stuffing Box Housing
10.Packing
11. Balance Sleeve
12.Packing Gland
13.O-ring
Sectional Arrangement Figure for Type D 、DG、DM、DF、DY Pump
14.Bearing
15.Wearing Ring Of First-stage
16. Wearing Ring
17. Diffuser Bush
18.Shaft
19. Shaft Sleeve
20.Balance Water Piping
21.Water Seal Piping
High Head Boiler Feed Water Pump is widely used in boiler water supply of industrial and mining enterprises and public institutions and urban domestic water supply. DG series pumps are especially suitable for boiler water supply, and can also be widely used in pressure vessel water supply, hot water circulation, high-rise building water supply, farmland irrigation, fire pressurization, hydraulic washing, food, brewing, medicine, chemical industry, aquaculture, environmental protection and other industries.
High pressure multistage pump Features
* High pressure multistage pump material: Cast iron, duct alloy, carbon steel, zinc free bronze, silicon brass or stainless steel construction (other materials available on request)
* High pressure multistage pump impeller: High efficiency impeller
* High pressure multistage pump operation:Durable, low noise, long life bearing
* High pressure multistage pump shaft seal:Premium quality mechanical seal
* High pressure multistage pump driven type:Electric or diesel drive
Performance Data | |||||||
Model | Capacity | Head m | Speed r/min | Motor Power (Kw) | Impeller Dia mm | Weight kg | |
m3/h | L/S | ||||||
D6-50x2 | 6.3 | 1.75 | 100 | 2950 | 11 | 198 | 140 |
D6-50x12 | 6.3 | 1.75 | 600 | 2950 | 55 | 198 | 340 |
D25-50x3 | 25 | 6.94 | 150 | 2950 | 30 | 196 | 220 |
D25-50x12 | 25 | 6.94 | 600 | 2950 | 110 | 196 | 409 |
D46-50x12 | 46 | 12.78 | 600 | 2950 | 160 | 210 | 475 |
D85-67x9 | 85 | 23.6 | 603 | 2950 | 250 | 235 | 1840 |
D120-50x2 | 120 | 33.3 | 100 | 2950 | 55 | 213 | 640 |
D120-50x9 | 120 | 33.3 | 450 | 2950 | 220 | 213 | 1200 |
D155-67x9 | 155 | 43.1 | 603 | 2950 | 450 | 235 | 1800 |
D360-40X10 | 360 | 100 | 400 | 1480 | 630 | 360 | 2550 |
D580-70X10 | 580 | 161.1 | 700 | 1480 | 1800 | 473 | 4120 |
D720-60x9 | 720 | 200 | 540 | 1480 | 1600 | 450 | 3900 |
Structure description of High Head Boiler Feed Water Pump
The main parts of the medium and low pressure feed water pump (head 50-684m) are generally made of high-quality cast iron, and the secondary high pressure feed water pump (head 409-1450m) is made of cast steel or stainless steel.
The pump housing part is mainly connected with bolts by the bearing body, front section, middle section, rear section, guide vane, etc. The center line of the suction port of the front section is vertical to the horizontal, and can also be a horizontal line. The midline of the latter spit out is perpendicular to the horizontal, or it can be a horizontal line.

This pump adopts packing seal or mechanical seal. Generally, it is better to use a mechanical seal when the temperature exceeds 90 degrees. When in use, the position of the packing and mechanical seal must be correct, and the tightness of the packing and mechanical seal must be appropriate, so that the fluid can seep drop by drop. Out is appropriate.
We also working for self balancing multistage pump type which is more easy for maintenance and lower cost for spare parts.
The self-flushing program prevents the coolant temperature from being too high, and the products sell well at the international market.
Contact us:
Shirley She
Tel: 0086 312 6795175
Cell: 0086 139 3227 8621 (whatsApp)
Email: admin@deponpump.com
Web: www.deponpump.com

The Applications of High Head Boiler Feed Water Pump
The flow rate of the boiler feed water pump is 25-150m3/h, and the head can reach 480-1100 meters. It can deliver high temperature clean water below 280℃, suitable for boiler water supply, factory and city water supply. It is suitable for conveying clean water with a temperature lower than 110°C or other non-corrosive liquids with physical and chemical properties similar to water.
High Head Boiler Feed Water Pump is widely used in boiler water supply of industrial and mining enterprises and public institutions and urban domestic water supply. DG series pumps are especially suitable for boiler water supply, and can also be widely used in pressure vessel water supply, hot water circulation, high-rise building water supply, farmland irrigation, fire pressurization, hydraulic washing, food, brewing, medicine, chemical industry, aquaculture, environmental protection and other industries.


Structure description of High Head Boiler Feed Water Pump
The main parts of the medium and low pressure feed water pump (head 50-684m) are generally made of high-quality cast iron, and the secondary high pressure feed water pump (head 409-1450m) is made of cast steel or stainless steel.
The pump housing part is mainly connected with bolts by the bearing body, front section, middle section, rear section, guide vane, etc. The center line of the suction port of the front section is vertical to the horizontal, and can also be a horizontal line. The midline of the latter spit out is perpendicular to the horizontal, or it can be a horizontal line.
This pump adopts packing seal or mechanical seal. Generally, it is better to use a mechanical seal when the temperature exceeds 90 degrees. When in use, the position of the packing and mechanical seal must be correct, and the tightness of the packing and mechanical seal must be appropriate, so that the fluid can seep drop by drop. Out is appropriate.
23 The self-flushing program prevents the coolant temperature from being too high, and the products sell well at the international market.



Contact us:
Shirley She
Tel: 0086 312 6795175
Cell: 0086 139 3227 8621 (whatsApp)
Email: admin@deponpump.com
Web: www.deponpump.com
Hot Tags: high head boiler feed water pump, made in China, China, manufacturers, factory, quotation, price list